Sun-Yeh (OM Range)

  • NEMA 4X, 5 & IP67 Enclosure for Outdoor Use (IP68 Optional extra)
  • Clutch-less Manual Transmission 
  • 2 additional auxiliary switches for voltage free open and closed indication
  • All models are equipped with an easily visible, continuous, mechanical position indicator on top of the actuator cover 
  • Built-in Thermal Protection
  • Gear trains are factory lubricated for actuators’ full life cycle
  • Available in 12v AC/DC; 24v AC/DC; 110V/220V -1 Phase; 400v/525v – 3 Phase
  • Fieldbus option: Modbus RTU RS485
  • Optional ATEX Enclosure (OME Range)

Valpes ER Premier Actuator

  • Enclosure: IP65
  • Multi-voltage actuator: 100V to 240V 50/60Hz (100V to 350V DC) and 24V 50/60Hz (24V DC)
  • On-off or 3 modulating points control
  • Secured manual override
  • Modular position indicator
  • Standard version: 90° – MULTIVOLT: operating time from 6s to 22s (without load)
  • FASTSTOP 10-20Nm version 12/24V AC/DC): operating time from 1.5s to 6s

Valpes VR / VS Range

  • Enclosure IP68: 2m / 72h (plastic cover); 5m / 72h (aluminium cover)
  • Multi-voltage actuator: 100V to 240V 50/60Hz (100V to 350V DC); 15V to 30V 50/60Hz (12V to 48V DC); 3-phase 50/60Hz 400V (not CSA)
  • 3 modulating points control or on-off (400V: 3 modulating points control)
  • Manual override: VR – secured manual override; VS – handwheel
  • Visual position indicator
  • Regulated anticondensation heater
  • Torque limiter monitored by software (except 400V)
  • Failure feedback relay (normal duty, failure) (except 400V)
  • Available with: BBPR – emergency backup; POSI – proportional control; 3 POSITIONS; POSI-BBPR; 3-POSITION-BBPR; BLUETOOTH®; Modbus-RTU

Valpes VT Range

  • Enclosure IP68: 2m / 72h (plastic cover); 5m / 72h (aluminium cover)
  • 230V 50/60Hz or 3-phase 50Hz 400V actuator
  • 3 modulating points control
  • VT600-1000Nm: F10/F12;  VT1500-2400Nm: F12/F14/F16
  • Manual override
  • Visual position indicator
  • Regulated anticondensation heater
  • Mechanical torque limiter
  • Failure feedback relay (normal duty, failure)
  • 90° standard version and 180° or 270° version (on request)
  • Version for marine applications. High durability coating, 15-year warranty

Valpes VT Plus Range

  • Enclosure IP68: 5m / 72h
  • Multivoltage actuator: 100V to 240V 50/60Hz (100V to 300V DC); 24V to 48V 50/60Hz (24V to 72V DC)
  • On-off, pulse and 3 modulating points control
  • Integrated 4-20mA or 0-10V positioning solution with feedback signal
  • Integrated Bluetooth® control (AXMART®)
  • RS485 connection
  • VT+ 600-1000Nm : F10/F12
  • VT+ 1500-2400Nm : F12/F14/F16
  • Manual override
  • Electronic torque limiter
  • Failure feedback relay (normal duty, failure)
  • Visual position indicator
  • Regulated anticondensation heater
  • Single multipin connector
  • Available with: BBPR – emergency backup; POSI – proportional control; POSI-BBPR;  BLUETOOTH®; Modbus-RTU

Valpes VSX / VRX Range

  • Enclosure IP68 and ATEX
  • Multi-voltage actuator: 100V to 240V 50/60Hz (100V to 350V DC); 15V to 30V 50/60Hz (12V to 48V DC); 3-phase 50/60Hz 400V (not CSA)
  • 3 modulating points control or on-off (400V: 3 modulating points control)
  • Manual override: VR – secured manual override; VS – handwheel
  • Visual position indicator
  • Regulated anticondensation heater
  • Torque limiter monitored by software (except 400V)
  • Failure feedback relay (normal duty, failure) (except 400V)
  • Available with: BBPR – emergency backup; POSI – proportional control; 3 POSITIONS; POSI-BBPR; 3-POSITION-BBPR; Modbus-RTU

Valpes VTX Range

  • Enclosure IP68 5 m / 72 h
  • VTX: 230V 50/60Hz and 3-phase 400V 50Hz
  • 3 modulating points control or on-off (400V and VTX: 3 modulating points control only)
  • VTX: F10/F12 star drive 36 mm
  • Manual override
  • Torque limiter monitored by software (except 400V) or mechanical (VTX)
  • Failure report relay (except 400V)
  • RS485 connection (except 400V and VTX)
  • Mechanical limit stops (adjustable for VSX and VTX)
  • Visual position indicator
  • Regulated anticondensation heater
  • 90° standard version and 180° or 270° version (on request)
  • Version for marine applications. High durability coating, 15-year warranty
  • Available with: BBPR – emergency backup; POSI – proportional control; 3 POSITIONS; POSI-BBPR; 3-POSITION-BBPR; Modbus-RTU

PS Automation PS-AMS PSQ-S

  • Enclosure – IP68
  • 24v DC; optional 100 – 240v AC; 24v AC; 400v AC
  • Maximum adjustable torque: 60 to 200Nm’s
  • Duty Cycle: S2 – 30min; S4 50% ED – 1200c/h
  • Motor protection by thermal monitoring with safety cut off.
  • Automatic commissioning 
  • 7 segment display for parameterisation
  • Five freely-programmable monostable relays switch outputs
  • Local controls
  • WLAN Access Point integrated for easy and wireless parameterisation with mobile devices.
  • Optional Failsafe PSCP – provided by super capacitors
  • Fieldbus ready – Profibus DP, CANopen; Profinet; Modbus RTU

PS Automation PS-AMS PSQ

  • Enclosure – IP67; IP68 Optional
  • 230VAC 1-, 155VAC 1-, 360-460VAC 3-, 24VAC/DC
  • Fully modulating actuator
  • Switching torque capability: 103Nm’s, 203Nm’s, 503Nm’s, 703Nm’s, 1003Nm’s, 1503Nm’s; 2003Nm’s; 2803Nm’s
  • Modulating torque capability: 65Nm’s, 125Nm’s, 250Nm’s, 350Nm’s, 500Nm’s, 750Nm’s; 1000Nm’s; 1400Nm’s
  • Duty Cycle: S2 – 30min; S4 50% ED – 1200c/h
  • Motor protection by electronic motor current monitoring with safety cut-off
  • Automatic commissioning by one key
  • Robust planetary gear and handwheel for manual operation
  • Programmable via optional local control or via USB Interface
  • Local controls
  • Optional Failsafe PSCP – provided by super capacitors
  • Fieldbus ready – Profibus DP, CANopen; additional interfaces on request

PS Automation PSQ-E

  • Enclosure – IP67; IP68 Optional
  • 230VAC 1-, 155VAC 1-, 24VAC 1-, 400VAC 3-, 24VDC
  • Switching torque capability: 100Nm’s, 130Nm’s (24VDC), 150Nm’s
  • Duty Cycle: S2 – 30min; S3/S4 1200c/h – 50% ED at 25 degrees Celcius
  • Motor protection by thermo switch (except 24VDC – Multifuse)
  • 2 additional position switches included (changeover contact)
  • Manual override by handwheel
  • Optional – Potentiometer, Current Position Transmitter

PS Automation PSR-E

  • Enclosure – IP65; IP67 Optional
  • 230VAC 1-, 155VAC 1-, 24VAC 1-, 24VDC
  • Switching torque capability: 25Nm’s; 50Nm’s
  • Duty Cycle: S2 – 20min; S3/S4 1200c/h – 50% ED at 25 degrees Celcius
  • Motor protection by thermo switch (except 24VDC – Multifuse)
  • 2 additional position switches included (changeover contact)
  • Manual override by push and turn knob
  • Optional – Potentiometer, Current Position Transmitter

Greatork Quarter turn Intelligent Actuator (AVAT Range)

  • IP68 Double Sealed Enclosure (7 metres submersible for 72 hours) – Optional enclosure EExdIIBT4 and EExdIICT4 ATEX Enclosure
  • Local Controls
  • Manual Override by lever
  • Non-intrusive commissioning via remote or pushbuttons
  • High-definition LCD screen providing 1% increments of valve position
  • Current Position Transmitter providing 4 to 20 milliamp feedback fitted as standard
  • Fieldbus options: Modbus, Profibus and Foundation Fieldbus
  • Available 220v AC, 400v 3 phase

Greatork Quarter turn Intelligent Actuator (AVAR Range)

  • IP67 Enclosure as standard; IP68 – Optional enclosure
  • Local Controls
  • Manual Override by handwheel with declutching mechanism
  • Non-intrusive commissioning via pushbuttons
  • High-definition LCD screen providing 1% increments of valve position
  • Current Position Transmitter providing 4 to 20 milliamp feedback fitted as standard
  • Available 220v AC, 400v 3 phase

T Crystal TCR Range

  • IP67 Enclosure
  • 24VAC/DC; 110VAC-1, 220VAC-1 (Please enquire about other voltages)
  • Torque outputs of 10Nm’s, 20Nm’s, 50Nm’s, 80Nm’s and 110Nm’s
  • Normal on/off model with option of failsafe
  • Intelligent on/off model with option of failsafe
  • Intelligent modulating model with option of failsafe
  • Intelligent timer model with option of failsafe
  • Intelligent wireless model with option of failsafe
  • High speed model available

T Crystal - TCN (Ex Range)

  • Explosion-proof level: Ex d IIB T6 Gb / Ex tD A21 IP68 T80
  • 12VDC, 24VAC/DC, 110VAC-1, 220VAC-1
  • Torque output of 20Nm’s
  • Intelligent on/off model with option of failsafe
  • Intelligent modulating model with option of failsafe
  • Intelligent timer model with option of failsafe

T Crystal TCN Range

  • IP67 Enclosure
  • 24VAC/DC; 110VAC-1, 220VAC-1 (Please enquire about other voltages)
  • Torque outputs of 200Nm’s, 400Nm’s, 1000Nm’s, 2000Nm’s
  • Normal on/off model 
  • Intelligent on/off model 
  • Intelligent modulating model 
  • Intelligent wireless model 
  • High speed model available