Sun-Yeh (OM Range) NEMA 4X, 5 & IP67 Enclosure for Outdoor Use (IP68 Optional extra)Clutch-less Manual Transmission 2 additional auxiliary switches for voltage free open and closed indicationAll models are equipped with an easily visible, continuous, mechanical position indicator on top of the actuator cover Built-in Thermal ProtectionGear trains are factory lubricated for actuators’ full life cycleAvailable in 12v AC/DC; 24v AC/DC; 110V/220V -1 Phase; 400v/525v – 3 PhaseFieldbus option: Modbus RTU RS485Optional ATEX Enclosure (OME Range) Documentation Valpes ER Premier Actuator Enclosure: IP65Multi-voltage actuator: 100V to 240V 50/60Hz (100V to 350V DC) and 24V 50/60Hz (24V DC)On-off or 3 modulating points controlSecured manual overrideModular position indicatorStandard version: 90° – MULTIVOLT: operating time from 6s to 22s (without load)FASTSTOP 10-20Nm version 12/24V AC/DC): operating time from 1.5s to 6s Documentation Valpes VR / VS Range Enclosure IP68: 2m / 72h (plastic cover); 5m / 72h (aluminium cover)Multi-voltage actuator: 100V to 240V 50/60Hz (100V to 350V DC); 15V to 30V 50/60Hz (12V to 48V DC); 3-phase 50/60Hz 400V (not CSA)3 modulating points control or on-off (400V: 3 modulating points control)Manual override: VR – secured manual override; VS – handwheelVisual position indicatorRegulated anticondensation heaterTorque limiter monitored by software (except 400V)Failure feedback relay (normal duty, failure) (except 400V)Available with: BBPR – emergency backup; POSI – proportional control; 3 POSITIONS; POSI-BBPR; 3-POSITION-BBPR; BLUETOOTH®; Modbus-RTU Documentation Valpes VT Range Enclosure IP68: 2m / 72h (plastic cover); 5m / 72h (aluminium cover)230V 50/60Hz or 3-phase 50Hz 400V actuator3 modulating points controlVT600-1000Nm: F10/F12; VT1500-2400Nm: F12/F14/F16Manual overrideVisual position indicatorRegulated anticondensation heaterMechanical torque limiterFailure feedback relay (normal duty, failure)90° standard version and 180° or 270° version (on request)Version for marine applications. High durability coating, 15-year warranty Documentation Valpes VT Plus Range Enclosure IP68: 5m / 72hMultivoltage actuator: 100V to 240V 50/60Hz (100V to 300V DC); 24V to 48V 50/60Hz (24V to 72V DC)On-off, pulse and 3 modulating points controlIntegrated 4-20mA or 0-10V positioning solution with feedback signalIntegrated Bluetooth® control (AXMART®)RS485 connectionVT+ 600-1000Nm : F10/F12VT+ 1500-2400Nm : F12/F14/F16Manual overrideElectronic torque limiterFailure feedback relay (normal duty, failure)Visual position indicatorRegulated anticondensation heaterSingle multipin connectorAvailable with: BBPR – emergency backup; POSI – proportional control; POSI-BBPR; BLUETOOTH®; Modbus-RTU Documentation Valpes VSX / VRX Range Enclosure IP68 and ATEXMulti-voltage actuator: 100V to 240V 50/60Hz (100V to 350V DC); 15V to 30V 50/60Hz (12V to 48V DC); 3-phase 50/60Hz 400V (not CSA)3 modulating points control or on-off (400V: 3 modulating points control)Manual override: VR – secured manual override; VS – handwheelVisual position indicatorRegulated anticondensation heaterTorque limiter monitored by software (except 400V)Failure feedback relay (normal duty, failure) (except 400V)Available with: BBPR – emergency backup; POSI – proportional control; 3 POSITIONS; POSI-BBPR; 3-POSITION-BBPR; Modbus-RTU Documentation Valpes VTX Range Enclosure IP68 5 m / 72 hVTX: 230V 50/60Hz and 3-phase 400V 50Hz3 modulating points control or on-off (400V and VTX: 3 modulating points control only)VTX: F10/F12 star drive 36 mmManual overrideTorque limiter monitored by software (except 400V) or mechanical (VTX)Failure report relay (except 400V)RS485 connection (except 400V and VTX)Mechanical limit stops (adjustable for VSX and VTX)Visual position indicatorRegulated anticondensation heater90° standard version and 180° or 270° version (on request)Version for marine applications. High durability coating, 15-year warrantyAvailable with: BBPR – emergency backup; POSI – proportional control; 3 POSITIONS; POSI-BBPR; 3-POSITION-BBPR; Modbus-RTU Documentation PS Automation PS-AMS PSQ-S Enclosure – IP6824v DC; optional 100 – 240v AC; 24v AC; 400v ACMaximum adjustable torque: 60 to 200Nm’sDuty Cycle: S2 – 30min; S4 50% ED – 1200c/hMotor protection by thermal monitoring with safety cut off.Automatic commissioning 7 segment display for parameterisationFive freely-programmable monostable relays switch outputsLocal controlsWLAN Access Point integrated for easy and wireless parameterisation with mobile devices.Optional Failsafe PSCP – provided by super capacitorsFieldbus ready – Profibus DP, CANopen; Profinet; Modbus RTU Documentation PS Automation PS-AMS PSQ Enclosure – IP67; IP68 Optional230VAC 1-, 155VAC 1-, 360-460VAC 3-, 24VAC/DCFully modulating actuatorSwitching torque capability: 103Nm’s, 203Nm’s, 503Nm’s, 703Nm’s, 1003Nm’s, 1503Nm’s; 2003Nm’s; 2803Nm’sModulating torque capability: 65Nm’s, 125Nm’s, 250Nm’s, 350Nm’s, 500Nm’s, 750Nm’s; 1000Nm’s; 1400Nm’sDuty Cycle: S2 – 30min; S4 50% ED – 1200c/hMotor protection by electronic motor current monitoring with safety cut-offAutomatic commissioning by one keyRobust planetary gear and handwheel for manual operationProgrammable via optional local control or via USB InterfaceLocal controlsOptional Failsafe PSCP – provided by super capacitorsFieldbus ready – Profibus DP, CANopen; additional interfaces on request Documentation PS Automation PSQ-E Enclosure – IP67; IP68 Optional230VAC 1-, 155VAC 1-, 24VAC 1-, 400VAC 3-, 24VDCSwitching torque capability: 100Nm’s, 130Nm’s (24VDC), 150Nm’sDuty Cycle: S2 – 30min; S3/S4 1200c/h – 50% ED at 25 degrees CelciusMotor protection by thermo switch (except 24VDC – Multifuse)2 additional position switches included (changeover contact)Manual override by handwheelOptional – Potentiometer, Current Position Transmitter Documentation PS Automation PSR-E Enclosure – IP65; IP67 Optional230VAC 1-, 155VAC 1-, 24VAC 1-, 24VDCSwitching torque capability: 25Nm’s; 50Nm’sDuty Cycle: S2 – 20min; S3/S4 1200c/h – 50% ED at 25 degrees CelciusMotor protection by thermo switch (except 24VDC – Multifuse)2 additional position switches included (changeover contact)Manual override by push and turn knobOptional – Potentiometer, Current Position Transmitter Documentation Greatork Quarter turn Intelligent Actuator (AVAT Range) IP68 Double Sealed Enclosure (7 metres submersible for 72 hours) – Optional enclosure EExdIIBT4 and EExdIICT4 ATEX EnclosureLocal ControlsManual Override by leverNon-intrusive commissioning via remote or pushbuttonsHigh-definition LCD screen providing 1% increments of valve positionCurrent Position Transmitter providing 4 to 20 milliamp feedback fitted as standardFieldbus options: Modbus, Profibus and Foundation FieldbusAvailable 220v AC, 400v 3 phase Documentation Greatork Quarter turn Intelligent Actuator (AVAR Range) IP67 Enclosure as standard; IP68 – Optional enclosureLocal ControlsManual Override by handwheel with declutching mechanismNon-intrusive commissioning via pushbuttonsHigh-definition LCD screen providing 1% increments of valve positionCurrent Position Transmitter providing 4 to 20 milliamp feedback fitted as standardAvailable 220v AC, 400v 3 phase Documentation T Crystal TCR Range IP67 Enclosure24VAC/DC; 110VAC-1, 220VAC-1 (Please enquire about other voltages)Torque outputs of 10Nm’s, 20Nm’s, 50Nm’s, 80Nm’s and 110Nm’sNormal on/off model with option of failsafeIntelligent on/off model with option of failsafeIntelligent modulating model with option of failsafeIntelligent timer model with option of failsafeIntelligent wireless model with option of failsafeHigh speed model available Documentation T Crystal - TCN (Ex Range) Explosion-proof level: Ex d IIB T6 Gb / Ex tD A21 IP68 T80℃12VDC, 24VAC/DC, 110VAC-1, 220VAC-1Torque output of 20Nm’sIntelligent on/off model with option of failsafeIntelligent modulating model with option of failsafeIntelligent timer model with option of failsafe Documentation T Crystal TCN Range IP67 Enclosure24VAC/DC; 110VAC-1, 220VAC-1 (Please enquire about other voltages)Torque outputs of 200Nm’s, 400Nm’s, 1000Nm’s, 2000Nm’sNormal on/off model Intelligent on/off model Intelligent modulating model Intelligent wireless model High speed model available Documentation